SAP PI/PO : How to solve error XI restart in qRFC not allowed ?
Hello guys,
Here is the solution.👇
1. Go to T-Code SMQR to deregister the queue.
2. Go to T-Code SXMB_ADM → Integration Engine Configuration ,then click on configuration as shown in picture below.
3. Create New Entry in Table Category = Monitor
Parameter = QRFC_RESTART_ALLOWED.
Current Value = 1.
4. Go to SMQR to again Register the queue.
5. Click on Queue and select the stopped queue.
6. Click on Execute LUW button for manual restart of Queue.
I hope it will help you.
Thanks
Here is the solution.👇
1. Go to T-Code SMQR to deregister the queue.
2. Go to T-Code SXMB_ADM → Integration Engine Configuration ,then click on configuration as shown in picture below.
3. Create New Entry in Table Category = Monitor
Parameter = QRFC_RESTART_ALLOWED.
Current Value = 1.
4. Go to SMQR to again Register the queue.
5. Click on Queue and select the stopped queue.
6. Click on Execute LUW button for manual restart of Queue.
I hope it will help you.
Thanks
1 Comments
Was stuck at this error days ago and couldn't find the solution on internet.
ReplyDeleteTried it and it solved the problem for me.
Thanks for sharing the solution